4.5-2.1 Moisture content. Determination of the moisture content of the
wood shall be made in accordance with ASTM D2016, electric moisture meter method.
Three readings shall be taken. Nonconformance to 3.3.2.2 shall constitute failure
of this test.
4.5-2.2 Static load. The truck shall be placed on a dry, smooth, level,
concrete floor, and loaded with a uniformly distributed load equal to 200 percent
of rated capacity as shown in table I. The truck shall support this load for
a period of I hour after which the load shall be removed and thetruck examined.
Nonconformance to 3.5.1 shall constitute failure of this test.
4.5-2.3 Rolling resistance. The truck, uniformly loaded up to its rated
capacity, shall be weighed and then placed on a dry, smooth, level, concrete
surface. The truck with rated load shall be accelerated to a minimum speed of
2 miles per hour MPH) by means of a suitable towing device employing a tension
dynamometer. The maximum &age reading of the dynamometer at this speed shall
be recorded over a minimum travel distance of 25 feet. This test shall be repeated
in the opposite direction so as to traverse the initial path and terminate at
the starting point. Nonconformance to 3.5.2 shall constitute failure of this
test.
4.6 Inspection of packaging.
4.6.1 Quality conformance inspection of pack.
4.6.1.1 Unit of product. For the purpose of inspection, a completed pack
prepared for shipment shall be considered a unit of product.
4.6.1.2 Sampling. Sampling for examination shall be in accordance with
MIL-STD-105.
4.6.1.3 Examination. Samples selected in accordance with 4.6.1.2 shall
be examined for the following defects. AQL shall be 2.5 percent defective.